Why does my boiler keep losing pressure?

The short answer

A boiler that keeps losing pressure almost always has water escaping somewhere: a small leak on a radiator or valve, a faulty pressure relief valve, or a failing expansion vessel. Topping up gets the heating back on, but if you are doing it more than every few weeks the cause needs finding and fixing.

Inside of a gas boiler with the casing removed for repair

What the pressure should be

Most combi and system boilers have a gauge on the front. With the heating off and the system cold, it should normally sit between 1 and 1.5 bar. When the heating is running it will rise a little, often to around 2 bar. That is normal.

Below 1 bar, many boilers will lock out and show a low-pressure fault code.

The four usual causes

  • A small leak. Check radiator valves, pipe joints under floors you can see, and around the boiler itself. Look for drips, damp patches or green or white crust on fittings.
  • You have just bled the radiators. Letting air out also lets some pressure out. Top up afterwards and it should hold.
  • The pressure relief valve is letting by. Look for a copper pipe running from the boiler to outside. If it is dripping, the valve may be faulty or the system may be over-pressurising.
  • The expansion vessel has lost its charge. If the pressure shoots up when the heating is on and drops when it is off, this is a likely cause.

How to top up the pressure

Most boilers are topped up with a filling loop, which is usually a silver braided hose or a built-in lever under the boiler. With the boiler off and cool, open the valves slowly until the gauge reads around 1.2 bar, then close them fully. Check your boiler manual for your model, as some have a key or a built-in filling lever.

If you are unsure, do not guess. Overfilling can make the pressure relief valve discharge.

When to call an engineer

If you need to top up more than once every few weeks, if you can see water around the boiler, or if the pressure climbs above 2.5 bar when the heating is on, get it checked. Leaving a slow leak can damage floors and ceilings, and running the boiler at the wrong pressure wears out parts.

We are Gas Safe registered (930171) and cover all of Surrey and Berkshire, including Guildford, Cobham, Virginia Water, Ascot and Sunningdale. Call 07939 923815, 24 hours a day.

Quick answers

What pressure should my boiler be?

Between 1 and 1.5 bar when the heating is off and the system is cold. It is normal for it to rise towards 2 bar when the heating is running.

Is it dangerous if my boiler pressure is low?

Low pressure is not dangerous in itself. The boiler will usually just stop working until it is topped up. Constant pressure loss does point to a leak or a faulty part that should be fixed.